Test methods and procedures.

§ 60.64 Test methods and procedures.

(a) In conducting the performance tests and relative accuracy tests required in § 60.8, you must use reference methods and procedures and the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).

(b)

(1)You must demonstrate compliance with the PM standards in § 60.62 using EPA method 5 or method 5I.

(2) Use Method 9 and the procedures in § 60.11 to determine opacity.

(3) Any sources other than kilns (including associated alkali bypass and clinker cooler) that are subject to the 10 percent opacity limit must follow the appropriate monitoring procedures in § 63.1350(f), (m)(1)through (4), (10) and (11), (o), and (p) of this chapter.

(c) Calculate and record the rolling 30 kiln operating day average emission rate daily of NOX and SO2 according to the procedures in paragraph (c)(1) of this section.

(1) Calculate the rolling 30 kiln operating day average emissions according to equation 6:

er12fe13.005.gif

Where:

E30D = 30 kiln operating day average emission rate of NOX or SO2, lb/ton of clinker. Ci = Concentration of NOX or SO2 for hour i, ppm. Qi = Volumetric flow rate of effluent gas for hour i, where Ci and Qi are on the same basis (either wet or dry), scf/hr. P = 30 days of clinker production during the same time period as the NOX or SO2 emissions measured, tons. k = Conversion factor, 1.194 × 10−7 for NOX and 1.660 × 10−7 for SO2, lb/scf/ppm. n = Number of kiln operating hours over 30 kiln operating days.