§ 60.64 Test methods and procedures.
(a) In conducting the performance tests and relative accuracy tests required in § 60.8, you must use reference methods and procedures and the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).
(b)
(1)You must demonstrate compliance with the PM standards in § 60.62 using EPA method 5 or method 5I.
(2) Use Method 9 and the procedures in § 60.11 to determine opacity.
(3) Any sources other than kilns (including associated alkali bypass and clinker cooler) that are subject to the 10 percent opacity limit must follow the appropriate monitoring procedures in § 63.1350(f), (m)(1)through (4), (10) and (11), (o), and (p) of this chapter.
(c) Calculate and record the rolling 30 kiln operating day average emission rate daily of NOX and SO2 according to the procedures in paragraph (c)(1) of this section.
(1) Calculate the rolling 30 kiln operating day average emissions according to equation 6:
Where: