Pretreatment standards for existing sources.

§ 421.135 Pretreatment standards for existing sources.

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in secondary lead process wastewater introduced into a POTW shall not exceed the following values:

(a) Subpart M—Battery Cracking.

PSES

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of lead scrap produced
Antimony1.299.579
Arsenic.936.384
Lead.189.087
Zinc.687.283
Ammonia (as N).000.000

(b) Subpart M—Blast, Reverberatory, or Rotary Furnace Wet Air Pollution Control.