Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

§ 421.133 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable:

(a) Subpart M—Battery Cracking.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of lead scrap produced
Antimony1.299.579
Arsenic.936.384
Lead.189.087
Zinc.687.283
Ammonia (as N).000.000

(b) Subpart M—Blast, Reverberatory, or Rotary Furnace Wet Air Pollution Control.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of lead produced from smelting
Antimony5.0382.245
Arsenic3.6281.488
Lead.731.339
Zinc2.6621.096
Ammonia (as N)0.0000.000