§ 421.106 Pretreatment standards for new sources.
Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in primary tungsten process wastewater introduced into a POTW shall not exceed the following values:
(a) Subpart J—Tungstic Acid Rinse.
PSNS
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
mg/kg (pounds per million pounds) of tungstic acid (as W) produced | ||
Lead | 11.490 | 5.333 |
Zinc | 41.850 | 17.230 |
Ammonia (as N) | 5,469.000 | 2,404.000 |
(b) Subpart J—Acid Leach Wet Air Pollution Control.
PSNS
Pollutant or pollutant property | Maximum for any one day | Maximum for monthly average |
---|---|---|
mg/kg (pounds per million) of tungstic acid (as W) produced | ||
Lead | 1.003 | 0.466 |
Zinc | 3.653 | 1.504 |
Ammonia (as N) | 477.400 | 209.900 |
(c) Subpart J—Alkali Leach Wash.
PSNS
Pollutant or pollutant property | Maximum for any one day | Maximum for monthly average |
---|---|---|
mg/kg (pounds per million) of sodium tungstate (as W) produced | ||
Lead | 0.000 | 0.000 |
Zinc | 0.000 | 0.000 |
Ammonia (as N) | 0.000 | 0.000 |