Pretreatment standards for new sources.

§ 421.106 Pretreatment standards for new sources.

Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in primary tungsten process wastewater introduced into a POTW shall not exceed the following values:

(a) Subpart J—Tungstic Acid Rinse.

PSNS

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of tungstic acid (as W) produced
Lead11.4905.333
Zinc41.85017.230
Ammonia (as N)5,469.0002,404.000

(b) Subpart J—Acid Leach Wet Air Pollution Control.

PSNS

Pollutant or pollutant property Maximum for any one day Maximum for monthly average
mg/kg (pounds per million) of tungstic acid (as W) produced
Lead1.0030.466
Zinc3.6531.504
Ammonia (as N)477.400209.900

(c) Subpart J—Alkali Leach Wash.

PSNS

Pollutant or pollutant property Maximum for any one day Maximum for monthly average
mg/kg (pounds per million) of sodium tungstate (as W) produced
Lead0.0000.000
Zinc0.0000.000
Ammonia (as N)0.0000.000