Pretreatment standards for existing sources.

§ 421.105 Pretreatment standards for existing sources.

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in primary tungsten process wastewater introduced into a POTW shall not exceed the following values:

(a) Subpart J—Tungstic Acid Rinse.

PSES

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of tungstic acid (as W) produced
Lead11.4905.333
Zinc41.85017.230
Ammonia (as N)5,469.0002,404.000

(b) Subpart J—Acid Leach Wet Air Pollution Control.

PSES

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of tungstic acid (as W) produced
Lead1.0030.466
Zinc3.6531.504
Ammonia (as N)477.400209.900

(c) Subpart J—Alkali Leach Wash.

PSES

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of tungstate (as W) produced
Lead0.0000.000
Zinc0.0000.000
Ammonia (as N)0.0000.000
This document is only available to subscribers. Please log in or purchase access.