§ 63.11582 What are my compliance requirements?
(a) You must demonstrate initial compliance with the emission reduction or 0.03 gr/dscf particulate matter (PM) concentration requirements specified in Table 1 of this subpart as follows:
(1) Using the methods specified in Table 2 of this subpart, or
(2) For existing sources only, using the results of an emissions test conducted in the past 5 years, provided the test meets the following requirements.
(i) The test was conducted under conditions that represent normal operation.
(ii) The test was performed using the methods specified in Table 3 of this subpart.
(iii) The test was conducted with a minimum of three separate test runs, as specified in § 63.7(e)(3).
(b) If you choose to demonstrate compliance with the emission reduction or 0.03 gr/dscf PM concentration requirements in Table 1 of this subpart by conducting an emissions test, you must follow the requirements specified in paragraphs (b)(1) through (b)(4) of this section and include the results in your Notification of Compliance Status Report (NOCSR) in accordance with § 63.11585(b)(3).
(1) You must conduct the tests under conditions that represent normal operation.
(2) You must perform the test using the methods specified in Table 3 of this subpart.
(3) You must conduct a minimum of three separate test runs for each performance test required in this section, as specified in § 63.7(e)(3).
(4) You must use the following equation to demonstrate compliance with the emission reduction requirements specified in Table 1 of this subpart: