Test methods and procedures.

§ 60.54 Test methods and procedures.

(a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).

(b) The owner or operator shall determine compliance with the particulate matter standard in § 60.52 as follows:

(1) The concentration (c12) of particulate matter, corrected to 12 percent CO2, shall be computed for each run using the following equation:

c12 = cs (12/%CO2)

where:

c12 = concentration of particulate matter, corrected to 12 percent CO2, g/dscm (gr/dscf). cs = concentration of particulate matter, g/dscm (gr/dscf). %CO2 = CO2 concentration, percent dry basis.

(2) Method 5 shall be used to determine the particulate matter concentration (cs). The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30 dscf).