§ 60.53b Standards for municipal waste combustor operating practices.
(a) On and after the date on which the initial performance test is completed or is required to be completed under § 60.8 of subpart A of this part, no owner or operator of an affected facility shall cause to be discharged into the atmosphere from that affected facility any gases that contain carbon monoxide in excess of the emission limits specified in table 1 of this subpart.
Table 1—Municipal Waste Combustor Operating Standards
Municipal waste combustor technology | Carbon monoxide emission limit (parts per million by volume) a | Averaging time (hours) b |
---|---|---|
Mass burn waterwall | 100 | 4 |
Mass burn refractory | 100 | 4 |
Mass burn rotary waterwall | 100 | 24 |
Modular starved air | 50 | 4 |
Modular excess air | 50 | 4 |
Refuse-derived fuel stoker | 150 | 24 |
Bubbling fluidized bed combustor | 100 | 4 |
Circulating fluidized bed combustor | 100 | 4 |
Pulverized coal/refuse-derived fuel mixed fuel-fired combustor | 150 | 4 |