§ 63.8688 What are my monitoring installation, operation, and maintenance requirements?
(a) You must install, operate, and maintain each continuous parameter monitoring system (CPMS) according to the following:
(1) The CPMS must complete a minimum of one cycle of operation for each successive 15-minute period.
(2) To determine the 3-hour average, you must:
(i) Have a minimum of four successive cycles of operation to have a valid hour of data.
(ii) Have valid data from at least three of four equally spaced data values for that hour from a CPMS that is not out-of-control according to your site-specific monitoring plan.
(iii) Determine the 3-hour average of all recorded readings for each operating day, except as stated in § 63.8690(c). You must have at least two of the three hourly averages for that period using only hourly average values that are based on valid data (i.e., not from out-of-control periods).
(3) You must record the results of each inspection, calibration, and validation check.
(b) For each temperature monitoring device, you must meet the requirements in paragraph (a) of this section and the following:
(1) Locate the temperature sensor in a position that provides a representative temperature.
(2) For a noncryogenic temperature range, use a temperature sensor with a minimum measurement sensitivity of 2.8 °C or 1.0 percent of the temperature value, whichever is larger.