§ 63.5995 What are my monitoring installation, operation, and maintenance requirements?
(a) For each operating parameter that you are required by § 63.5994(e)(1) to monitor, you must install, operate, and maintain a continuous parameter monitoring system (CPMS) according to the requirements in § 63.5990(e) and (f) and in paragraphs (a)(1) through (6) of this section.
(1) You must operate your CPMS at all times that the process is operating.
(2) You must collect data from at least four equally spaced periods each hour.
(3) For at least 75 percent of the hours in an operating day, you must have valid data (as defined in your site-specific monitoring plan) for at least four equally spaced periods each hour.
(4) For each hour that you have valid data from at least four equally spaced periods, you must calculate the hourly average value using all valid data.
(5) You must calculate the daily average using all of the hourly averages calculated according to paragraph (a)(3) of this section for the 24-hour period.