§ 63.1187 What do I need to know about operations, maintenance, and monitoring plans?
(a) An operations, maintenance, and monitoring plan must be submitted to the Administrator for review and approval as part of your application for the title V permit.
(b) The operations, maintenance, and monitoring plan must include the following:
(1) Process and control device parameters you will monitor to determine compliance, along with established operating levels or ranges for each process or control device.
(2) A monitoring schedule.
(3) Procedures for properly operating and maintaining control devices used to meet the standards in §§ 63.1178 and 63.1179 of this subpart. These procedures must include an inspection of each incinerator at least once per year. At a minimum, you must do the following as part of an incinerator inspection: