Don't show this message again
§ 266.108 Small quantity on-site burner exemption.
(a) Exempt quantities. Owners and operators of facilities that burn hazardous waste in an on-site boiler or industrial furnace are exempt from the requirements of this subpart provided that:
(1) The quantity of hazardous waste burned in a device for a calendar month does not exceed the limits provided in the following table based on the terrain-adjusted effective stack height as defined in § 266.106(b)(3):
Exempt Quantities for Small Quantity Burner Exemption
Terrain-adjusted effective stack height of device (meters) | Allowable hazardous waste burning rate (gallons/month) | Terrain-adjusted effective stack height of device (meters) | Allowable hazardous waste burning rate (gallons/month) |
---|---|---|---|
0 to 3.9 | 0 | 40.0 to 44.9 | 210 |
4.0 to 5.9 | 13 | 45.0 to 49.9 | 260 |
6.0 to 7.9 | 18 | 50.0 to 54.9 | 330 |
8.0 to 9.9 | 27 | 55.0 to 59.9 | 400 |
10.0 to 11.9 | 40 | 60.0 to 64.9 | 490 |
12.0 to 13.9 | 48 | 65.0 to 69.9 | 610 |
14.0 to 15.9 | 59 | 70.0 to 74.9 | 680 |
16.0 to 17.9 | 69 | 75.0 to 79.9 | 760 |
18.0 to 19.9 | 76 | 80.0 to 84.9 | 850 |
20.0 to 21.9 | 84 | 85.0 to 89.9 | 960 |
22.0 to 23.9 | 93 | 90.0 to 94.9 | 1,100 |
24.0 to 25.9 | 100 | 95.0 to 99.9 | 1,200 |
26.0 to 27.9 | 110 | 100.0 to 104.9 | 1,300 |
28.0 to 29.9 | 130 | 105.0 to 109.9 | 1,500 |
30.0 to 34.9 | 140 | 110.0 to 114.9 | 1,700 |
35.0 to 39.9 | 170 | 115.0 or greater | 1,900 |