Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

§ 471.102 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):

(a) Metal powder production atomization wastewater.

Subpart J—BAT

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/off-kg (pounds per million off-pounds) of powder wet atomized
Copper9.585.04
Cyanide1.460.605
Lead2.121.01

(b) Sizing spent emulsions.

Subpart J—BAT

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/off-kg (pounds per million off-pounds) or powder sized
Copper0.0280.015
Cyanide0.0040.002
Lead0.0060.003