Pretreatment standards for existing sources (PSES).

§ 461.74 Pretreatment standards for existing sources (PSES).

(a) Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources:

(1) Subpart G—Wet Amalgamated Powder Anode—PSES.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
Metric units—mg/kg of zinc
English units—pounds per 1,000,000 pounds of zinc
Chromium0.240.099
Mercury0.140.055
Silver0.230.093
Zinc0.800.34
Manganese0.370.16

(2) Subpart G—Gelled Amalgam Anodes—PSES.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
Metric units—mg/kg of zinc
English units—pounds per 1,000,000 pounds of zinc
Chromium0.0300.12
Mercury0.0170.006
Silver0.0280.012
Zinc0.0990.042
Manganese0.0460.020

(3) Subpart G—Zinc Oxide Formed Anodes—PSES.