§ 421.315 Pretreatment standards for existing sources.
Except as provided in 40 CFR 403.7, any existing source subject to this subpart which introduces polutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in secondary tungsten and cobalt process wastewater introduced into a POTW shall not exceed the following values:
(a) Tungsten detergent wash and rinse.
PSES for the Secondary Tungsten and Cobalt Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
mg/kg (pounds per million pounds) of tungsten scrap washed | ||
Copper | 0.250 | 0.119 |
Nickel | 0.107 | 0.072 |
Ammonia (as N) | 25.990 | 11.430 |
Cobalt | 0.538 | 0.236 |
Tungsten | 0.679 | 0.302 |
(b) Tungsten leaching acid.
PSES for the Secondary Tungsten and Cobalt Subcategory
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
mg/kg (pounds per million pounds) of tungsten produced | ||
Copper | 3.291 | 1.569 |
Nickel | 1.414 | 0.951 |
Ammonia (as N) | 342.700 | 150.700 |
Cobalt | 7.096 | 3.111 |
Tungsten | 8.947 | 3.985 |