§ 420.103 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
(a) Cold rolling mills—(1) Recirculation—single stand.
Subpart J
Pollutant or pollutant property | BAT effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
Chromium 1 | 0.0000209 | 0.0000084 |
Lead | 0.0000094 | 0.0000031 |
Nickel 1 | 0.0000188 | 0.0000063 |
Zinc | 0.0000063 | 0.0000021 |
Naphthalene | 0.0000021 | |
Tetrachloroethylene | 0.0000031 |
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.
(2) Recirculation—multiple stands.