§ 147.3108 Plugging Class I, II, and III wells.
In addition to the requirements of § 146.10 of this chapter, owners and operators shall comply with the following when plugging a well:
(a) For Class I and III wells:
(1) The well shall be filled with mud from the bottom of the well to a point one hundred (100) feet below the top of the highest disposal or injection zone and then with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone.
(2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of the surface casing to a point at least five (5) feet above the top of the lowest USDW.
(3) A final cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5) feet below the ground surface.