§ 1039.645 What special provisions apply to engines used for transportation refrigeration units?
Manufacturers may choose to use the provisions of this section for engines used in transportation refrigeration units (TRUs). The operating restrictions and characteristics in paragraph (f) of this section define engines that are not used in TRUs. All provisions of this part apply for TRU engines, except as specified in this section.
(a) You may certify engines under this section with the following special provisions:
(1) The engines are not subject to the transient emission standards of subpart B of this part.
(2) The steady-state emission standards in subpart B of this part apply for emissions measured over the steady-state test cycle described in paragraph (b) of this section instead of the otherwise applicable duty cycle described in § 1039.505.
(b) Measure steady-state emissions using the procedures specified in § 1039.505, except for the duty cycles, as follows:
(1) The following duty cycle applies for discrete-mode testing:
Table 1 of § 1039.645—Discrete-Mode Cycle for TRU Engines
Mode number | Engine speed 1 | Torque (percent) 2 | Weighting factors |
---|---|---|---|
1 | Maximum test speed | 75 | 0.25 |
2 | Maximum test speed | 50 | 0.25 |
3 | Intermediate test speed | 75 | 0.25 |
4 | Intermediate test speed | 50 | 0.25 |