§ 60.542 Standards for volatile organic compounds.
(a) On and after the date on which the initial performance test, required by § 60.8, is completed, but no later than 180 days after initial startup, each owner or operator subject to the provisions of this subpart shall comply with the following conditions:
(1) For each undertread cementing operation:
(i) Discharge into the atmosphere no more than 25 percent of the VOC used (75 percent emission reduction) for each month; or
(ii) Maintain total (uncontrolled) VOC use less than or equal to the levels specified below, depending upon the duration of the compliance period:
(A) 3,870 kg (8,531 lb) of VOC per 28 days,
(B) 4,010 kg (8,846 lb) of VOC per 29 days,
(C) 4,150 kg (9,149 lb) of VOC per 30 days,
(D) 4,280 kg (9,436 lb) of VOC per 31 days, or
(E) 4,840 kg (10,670 lb) of VOC per 35 days.
(2) For each sidewall cementing operation:
(i) Discharge into the atmosphere no more than 25 percent of the VOC used (75 percent emission reduction) for each month; or
(ii) Maintain total (uncontrolled) VOC use less than or equal to the levels specified below, depending upon the duration of the compliance period: