§ 60.50a Applicability and delegation of authority.
(a) The affected facility to which this subpart applies is each municipal waste combustor unit with a municipal waste combustor unit capacity greater than 225 megagrams per day (250 tons per day) of municipal solid waste for which construction, modification, or reconstruction is commenced as specified in paragraphs (a)(1) and (a)(2) of this section.
(1) Construction is commenced after December 20, 1989 and on or before September 20, 1994.
(2) Modification or reconstruction is commenced after December 20, 1989 and on or before June 19, 1996.
(b) [Reserved]
(c) Any unit combusting a single-item waste stream of tires is not subject to this subpart if the owner or operator of the unit:
(1) Notifies the Administrator of an exemption claim; and
(2) Provides data documenting that the unit qualifies for this exemption.
(d) Any cofired combustor, as defined under § 60.51a, located at a plant that meets the capacity specifications in paragraph (a) of this section is not subject to this subpart if the owner or operator of the cofired combustor: