Pretreatment standards for new sources.

§ 421.266 Pretreatment standards for new sources.

Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in secondary precious metals process wastewater introduced into a POTW shall not exceed the following values:

(a) Furnace wet air pollution control.

PSNS for the Secondary Precious Metals Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/troy ounce of precious metals, including silver, incinerated or smelted
Copper5.7602.745
Cyanide (total)0.9000.360
Zinc4.5901.890
Combined metals1.350
Ammonia (as N)599.900263.700

(b) Raw material granulation.

PSNS for the Secondary Precious Metals Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/troy ounce of precious metals, in the granulated raw material
Copper0.8190.390
Cyanide (total)0.1280.051
Zinc0.6530.269
Combined metals0.192
Ammonia85.31037.500

(c) Spent plating solutions.