Don't show this message again
§ 420.95 Pretreatment standards for existing sources (PSES).
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources.
(a) Sulfuric acid (spent acid solutions and rinse waters)—(1) Rod, wire, and coil.
Subpart I
Pollutant or pollutant property | Pretreatment standards for existing sources | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
Lead | 0.000526 | 0.000175 |
Zinc | 0.000701 | 0.000234 |
(2) Bar, billet, and bloom.
Subpart I
Pollutant or pollutant property | Pretreatment standards for existing sources | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
Lead | 0.000169 | 0.0000563 |
Zinc | 0.000225 | 0.0000751 |
(3) Strip, sheet, and plate.
Subpart I
Pollutant or pollutant property | Pretreatment standards for existing sources | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
Lead | 0.000338 | 0.000113 |
Zinc | 0.000451 | 0.000150 |