Pretreatment standards for existing sources.

§ 467.65 Pretreatment standards for existing sources.

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in aluminum forming process wastewater introduced into a POTW shall not exceed the values set forth below:

Subpart F

Core

Pollutant or pollutant property PSES
Maximum for any 1 day Maximum for monthly average
mg/off-kg (lb/million off-lbs) of aluminum drawn with emulsions or soaps
Chromium0.2050.084
Cyanide0.1350.056
Zinc0.6810.285
TTO0.32
Oil and grease (alternate monitoring parameter)2512