§ 63.1004 Instrument and sensory monitoring for leaks.
(a) Monitoring for leaks. The owner or operator of a regulated source subject to this subpart shall monitor all regulated equipment as specified in paragraph (a)(1) of this section for instrument monitoring and paragraph (a)(2) of this section for sensory monitoring.
(1) Instrument monitoring for leaks. (i) Valves in gas and vapor service and in light liquid service shall be monitored pursuant to § 63.1006(b).
(ii) Pumps in light liquid service shall be monitored pursuant to § 63.1007(b).
(iii) Connectors in gas and vapor service and in light liquid service shall be monitored pursuant to § 63.1008(b).
(iv) Agitators in gas and vapor service and in light liquid service shall be monitored pursuant to § 63.1009(b).
(v) Pressure relief devices in gas and vapor service shall be monitored pursuant to § 63.1011(c).
(vi) Compressors designated to operate with an instrument reading less than 500 parts per million as described in § 63.1003(e), shall be monitored pursuant to § 63.1012(f).
(2) Sensory monitoring for leaks. (i) Pumps in light liquid service shall be observed pursuant to § 63.1007(b)(3) and (e)(1)(v).
(ii) [Reserved]
(iii) Agitators in gas and vapor service and in light liquid service shall be observed pursuant to § 63.1009(b)(3) or (e)(1)(iv).
(iv) [Reserved]
(b) Instrument monitoring methods. Instrument monitoring, as required under this subpart, shall comply with the requirements specified in paragraphs (b)(1) through (b)(6) of this section.