§ 63.2492 How do I determine whether my process vent, storage tank, or equipment is in ethylene oxide service?
To determine if process vents, storage tanks, and equipment leaks are in ethylene oxide service as defined in § 63.2550(i), you must comply with the requirements in paragraphs (a) through (c) of this section, as applicable.
(a) For each batch process vent or continuous process vent stream, you must measure the flow rate and concentration of ethylene oxide of each process vent as specified in paragraphs (a)(1) through (5) of this section.
(1) Measurements must be made prior to any dilution of the vent streams.
(2) Measurements may be made on the combined vent streams at an MCPU or for each separate vent stream.
(3) Method 1 or 1A of 40 CFR part 60, appendix A–1, as appropriate, must be used for the selection of the sampling sites. For vents smaller than 0.10 meter in diameter, sample at one point at the center of the duct.
(4) The gas volumetric flow rate must be determined using Method 2, 2A, 2C, 2D, 2F, or 2G of 40 CFR part 60, appendices A–1 and A–2, as appropriate.