§ 97.930 General monitoring, recordkeeping, and reporting requirements.
The owners and operators, and to the extent applicable, the designated representative, of a Texas SO2 Trading Program unit, shall comply with the monitoring, recordkeeping, and reporting requirements as provided in this subpart and subparts F and G of part 75 of this chapter. For purposes of applying such requirements, the definitions in § 97.902 and in § 72.2 of this chapter shall apply, the terms “affected unit,” “designated representative,” and “continuous emission monitoring system” (or “CEMS”) in part 75 of this chapter shall be deemed to refer to the terms “Texas SO2 Trading Program unit,” “designated representative,” and “continuous emission monitoring system” (or “CEMS”) respectively as defined in § 97.902. The owner or operator of a unit that is not a Texas SO2 Trading Program unit but that is monitored under § 75.16(b)(2) of this chapter shall comply with the same monitoring, recordkeeping, and reporting requirements as a Texas SO2 Trading Program unit.
(a) Requirements for installation, certification, and data accounting. The owner or operator of each Texas SO2 Trading Program unit shall:
(1) Install all monitoring systems required under this subpart for monitoring SO2 mass emissions and individual unit heat input (including all systems required to monitor SO2 concentration, stack gas moisture content, stack gas flow rate, CO2 or O2 concentration, and fuel flow rate, as applicable, in accordance with §§ 75.11 and 75.16 of this chapter);