§ 1090.500 Gasoline produced from blending transmix into PCG.
(a) Applicability. (1) Except as specified in paragraph (a)(2) of this section, a transmix blender that blends transmix into PCG must comply with the requirements of this section.
(2) Small volumes of fuel that are captured in pipeline sumps or trapped in pipeline pumps or valve manifolds and that are injected back into batches of gasoline or diesel fuel are exempt from the requirements in this section.
(b) Requirements. (1) The distillation end-point of the resultant transmix-blended gasoline must not exceed 437 degrees Fahrenheit.
(2) The resultant transmix-blended gasoline must meet the downstream sulfur per-gallon standard in § 1090.205(c) and the applicable RVP standard in § 1090.215.
(3) The transmix blender must comply with the recordkeeping requirements in § 1090.1255.
(4) The transmix blender must maintain and follow a written quality assurance program that meets the requirements of paragraph (c) of this section.