Emission standards.

§ 63.882 Emission standards.

(a) Emission limits for gas-fired glass-melting furnaces. For each existing, new, or reconstructed gas-fired glass-melting furnace, on and after the compliance date specified in § 63.887 whichever date is earlier, you must not discharge or cause to be discharged into the atmosphere emissions in excess of 0.00025 lb of chromium compounds per ton of glass pulled (0.25 lb per thousand tons glass pulled).

(b) Operating limits. On and after the date on which the performance test required by §§ 63.7 and 63.1384 is completed, you must operate all affected control equipment and processes according to the following requirements.

(1)

(i) You must initiate corrective action within one hour of an alarm from a bag leak detection system and complete corrective actions in a timely manner according to the procedures in the operations, maintenance, and monitoring plan.

(ii) You must implement a Quality Improvement Plan consistent with the compliance assurance monitoring provisions of 40 CFR part 64, subpart D when the bag leak detection system alarm is sounded for more than 5 percent of the total operating time in a 6-month block reporting period.