§ 471.72 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):
(a) Extrusion spent lubricants—subpart G—BAT. There shall be no discharge of process wastewater pollutants.
(b) Extrusion tool contact cooling water.
Subpart G—BAT
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
mg/off-kg (pounds per million off-pounds) of uranium extruded | ||
Cadmium | 0.007 | 0.003 |
Chromium | 0.013 | 0.005 |
Copper | 0.044 | 0.021 |
Lead | 0.010 | 0.005 |
Nickel | 0.019 | 0.013 |
Fluoride | 2.05 | 0.908 |
Molybdenum | 0.173 | 0.077 |
(c) Heat treatment contact cooling water.
Subpart G—BAT
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average |
---|---|---|
mg/off-kg (pounds per million off-pounds) of extruded or forged uranium heat treated | ||
Cadmium | 0.006 | 0.003 |
Chromium | 0.012 | 0.005 |
Copper | 0.040 | 0.019 |
Lead | 0.009 | 0.004 |
Nickel | 0.017 | 0.012 |
Fluoride | 1.86 | 0.827 |
Molybdenum | 0.158 | 0.070 |