Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

§ 421.332 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable technology currently available:

(a) Sand drying wet air pollution control.

BPT Limitations for the Primary Zirconium and Hafnium Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of zirconium dioxide and hafnium dioxide produced
Chromium (total)0.2500.102
Cyanide (total)0.1650.068
Lead0.2390.114
Nickel1.0910.721
Ammonia (as N)75.71033.280
Total suspended solids23.29011.080
pH( 1)( 1)

1 Within the range of 7.5 to 10.0 at all times.

(b) Sand chlorination off-gas wet air pollution control.

BPT Limitations for the Primary Zirconium and Hafnium Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of zironium dioxide and hafnium dioxide produced
Chromium (total)19.1307.825
Cyanide (total)12.6105.216
Lead18.2608.694
Nickel83.46055.210
Ammonia (as N)5,795.0002,547.000
Total suspended solids1,782.000847.700
pH( 1)( 1)

1 Within the range of 7.5 to 10.0 at all times.

(c) Sand chlorination area-vent wet air pollution control.

BPT Limitations for the Primary Zirconium and Hafnium Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of zirconium dioxide and hafnium dioxide produced
Chromium (total)3.7511.534
Cyanide (total)2.4721.023
Lead3.5801.705
Nickel16.37010.830
Ammonia (as N)1,136.000449.500
Total suspended solids349.500166.200
pH( 1)( 1)

1 Within the range of 7.5 to 10.0 at all times.

(d) SiCl4 purification wet air pollution control.

BPT Limitations for the Primary Zirconium and Hafnium Subcategory

This document is only available to subscribers. Please log in or purchase access.