§ 1915.509 Definitions applicable to this subpart.
Alarm—a signal or message from a person or device that indicates that there is a fire, medical emergency, or other situation that requires emergency response or evacuation. At some shipyards, this may be called an “incident” or a “call for service.”
Alarm system—a system that warns employees at the worksite of danger.
Body harness—a system of straps that may be secured about the employee in a manner that will distribute the fall arrest forces over at least the thighs, shoulders, chest, and pelvis, with means for attaching it to other components of a personal fall arrest system.
Class II standpipe system—a 1 1⁄2 inch (3.8 cm) hose system which provides a means for the control or extinguishment of incipient stage fires.
Contract employer—an employer, such as a painter, joiner, carpenter, or scaffolding sub-contractor, who performs work under contract to the host employer or to another employer under contract to the host employer at the host employer's worksite. This excludes employers who provide incidental services that do not influence shipyard employment (such as mail delivery or office supply services).
Dangerous atmosphere—an atmosphere that may expose employees to the risk of death, incapacitation, injury, acute illness, or impairment of ability to self-rescue (i.e., escape unaided from a confined or enclosed space).
Designated area—an area established for hot work after an inspection that is free of fire hazards.
Drop Test—a method utilizing gauges to ensure the integrity of an oxygen fuel gas burning system. The method requires that the burning torch is installed to one end of the oxygen and fuel gas lines and then the gauges are attached to the other end of the hoses. The manifold or cylinder supply valve is opened and the system is pressurized. The manifold or cylinder supply valve is then closed and the gauges are watched for at least sixty (60) seconds. Any drop in pressure indicates a leak.