§ 146.32 Construction requirements.
(a) All new Class III wells shall be cased and cemented to prevent the migration of fluids into or between underground sources of drinking water. The Director may waive the cementing requirement for new wells in existing projects or portions of existing projects where he has substantial evidence that no contamination of underground sources of drinking water would result. The casing and cement used in the construction of each newly drilled well shall be designed for the life expectancy of the well. In determining and specifying casing and cementing requirements, the following factors shall be considered:
(1) Depth to the injection zone;
(2) Injection pressure, external pressure, internal pressure, axial loading, etc.;
(3) Hole size;
(4) Size and grade of all casing strings (wall thickness, diameter, nominal weight, length, joint specification, and construction material);