Applicability.

§ 63.360 Applicability.

(a) All sterilization sources using 1 ton (see definition) in sterilization or fumigation operations are subject to the emissions standards in § 63.362, except as specified in paragraphs (b) through (e) of this section. Owners or operators of sources using 1 ton (see definition) subject to the provisions of this subpart must comply with the requirements of subpart A, of this part according to the applicability of subpart A of this part to such sources in Table 1 of this section.

Table 1 of Section 63.360—General Provisions Applicability to Subpart O

Reference Applies to sources using 10 tons in subpart O aApplies to sources using 1 to 10 tons in subpart O aComment
63.1(a)(1)YesAdditional terms defined in § 63.361; when overlap between subparts A and O occurs, subpart O takes precedence.
63.1(a)(2)Yes
63.1(a)(3)Yes
63.1(a)(4)YesSubpart O clarifies the applicability of each paragraph in subpart A to sources subject to subpart O.
63.1(a)(5)NoReserved.
63.1(a)(6)Yes
63.1(a)(7)Yes
63.1.1(a)(8)Yes
63.1(a)(9)NoReserved.
63.1(a)(10)Yes
63.1(a)(11)Yes§ 63.366(a) of subpart O also allows report submissions via fax and on electronic media.
63.1(a)(12)–(14)Yes
63.1(b)(1)–(2)Yes
63.1(b)(3)No§ 63.367 clarifies the applicability of recordkeeping requirements for sources that determine they are not subject to the emissions standards.
63.1(c)(1)YesSubpart O clarifies the applicability of each paragraph in subpart A to sources subject to subpart O in this table.
63.1(c)(2)Yes§ 63.360(f) exempts area sources subject to this subpart from the obligation to obtain Title V operating permits.
63.1(c)(3)NoReserved.
63.1(c)(4)Yes
63.1(c)(5)No§ 63.360 specifies applicability.
63.1(c)(6)Yes
63.1(d)NoReserved.
63.1(e)Yes
63.2YesAdditional terms defined in § 63.361; when overlap between subparts A and O occurs, subpart O takes precedence.
63.3YesOther units used in subpart O are defined in the text of subpart O.
63.4(a)(1)–(3)Yes
63.4(a)(4)NoReserved.
63.4(a)(5)Yes
63.4(b)Yes
63.4(c)Yes
63.5(a)No§ 63.366(b)(1) contains applicability requirements for constructed or reconstructed sources.
63.5(b)(1)YesNo
63.5(b)(2)NoReserved.
63.5(b)(3)NoSee § 63.366(b)(2).
63.5(b)(4)YesNo
63.5(b)(5)YesNo
63.5(b)(6)YesNo
63.5(c)NoReserved.
63.5(d)(1)–(2)NoSee § 63.366(b)(3).
63.5(d)(3)–(4)YesNo
63.5(e)YesNo
63.5(f)(1)–(2)NoSee § 63.366(b)(4).
63.6(a)(1)Yes
63.6(a)(2)No§ 63.360 specifies applicability.
63.6(b)–(c)No§ 63.360(g) specifies compliance dates for sources.
63.6(d)NoReserved.
63.6(e)NoSubpart O does not contain any operation and maintenance plan requirements.
63.6(f)(1)No§ 63.362(b) specifies when the standards apply.
63.6(f)(2)(i)Yes
63.6(f)(2)(ii)No§ 63.363 specifies parameters for determining compliance.
63.6(f)(2)(iii)–(iv)Yes
63.6(f)(2)(v)No
63.6(f)(3)Yes
63.6(g)Yes
63.6(h)NoSubpart O does not contain any opacity or visible emission standards.
63.6(i)(1)–(14)Yes
63.6(i)(15)NoReserved
63.6(i)(16)Yes
63.6(j)Yes
63.7(a)(1)Yes
63.7(a)(2)Yes
63.7(a)(3)Yes
63.7(b)Yes
63.7(c)YesNo
63.7(d)YesNo
63.7(e)Yes§ 63.365 also contains test methods specific to sources subject to the emissions standards.
63.7(f)Yes
63.7(g)(1)Yes
63.7(g)(2)NoReserved
63.7(g)(3)Yes
63.7(h)Yes
63.8(a)(1)Yes
63.8(a)(2)Yes
63.8(a)(3)NoReserved
63.8(a)(4)Yes
63.8(b)(1)Yes
63.8(b)(2)Yes
63.8(b)(3)No
63.8(c)(1) (i)–(ii)NoA startup, shutdown, and malfunction plan is not required for these standards.
63.8(c)(1)(iii)Yes
63.8(c)(2)–(3)Yes
63.8(c)(4)–(5)NoFrequency of monitoring measurements is provided in § 63.364; opacity monitors are not required for these standards.
63.8(c)(6)NoPerformance specifications for gas chromatographs and temperature monitors are contained in § 63.365.
63.8(c)(7)(i)(A)–(B)NoPerformance specifications for gas chromatographs and temperature monitors are contained in § 63.365.
63.8(c)(7)(i)(C)NoOpacity monitors are not required for these standards.
63.8(c)(7)(ii)NoPerformance specifications for gas chromatographs and temperature monitors are contained in § 63.365.
63.8(c)(8)No
63.8(d)YesNo
63.8(e)(1)Yes
63.8(e)(2)Yes
63.8(e)(3)YesNo
63.8(e)(4)Yes
63.8(e)(5)(i)Yes
63.8(e)(5)(ii)NoOpacity monitors are not required for these standards.
63.8(f)(1)–(5)Yes
63.8(f)(6)No
63.8(g)(1)Yes
63.8(g)(2)No
63.8(g)(3)–(5)Yes
63.9(a)Yes
63.9(b)(1)–(i)Yes
63.9(b)(1)(ii)–(iii)No§ 63.366(c)(1)(i) contains language for sources that increase usage such that the source becomes subject to the emissions standards.
63.9(b)(2)–(3)Yes§ 63.366(c)(3) contains additional information to be included in the initial report for existing and new sources.
63.9(b)(4)–(5)No§ 63.366(c)(1)(ii) and (iii) contains requirements for new or reconstructed sources subject to the emissions standards.
63.9(c)Yes
63.9(d)No
63.9(e)Yes
63.9(f)NoOpacity monitors are not required for these standards.
63.9(g)(1)Yes
63.9(g)(2)–(3)NoOpacity monitors and relative accuracy testing are not required for these standards.
63.9(h)(1)–(3)Yes
63.9(h)(4)NoReserved.
63.9(h)(5)No§ 63.366(c)(2) instructs sources to submit actual data.
63.9(h)(6)Yes
63.9(i)Yes
63.9(j)Yes
63.9(k)YesOnly as specified in § 63.9(j).
63.10(a)Yes
63.10(b)(1)Yes
63.10(b)(2)(i)NoNot applicable due to batch nature of the industry.
63.10(b)(2)(ii)Yes
63.10(b)(2)(iii)No
63.10(b)(2)(iv)–(v)NoA startup, shutdown, and malfunction plan is not required for these standards.
63.10(b)(2)(vi)–(xii)Yes
63.10(b)(2)(xiii)No
63.10(b)(2)(xiv)Yes
63.10(b)(3)No§ 63.367 (b) and (c) contains applicability determination requirements.
63.10(c)(1)Yes
63.10(c)(2)–(4)NoReserved.
63.10(c)(5)Yes
63.10(c)(6)No
63.10(c)(7)NoNot applicable due to batch nature of the industry.
63.10(c)(8)Yes
63.10(c)(9)No
63.10(c)(10)–(13)Yes
63.10(c)(14)YesNo
63.10(c)(15)NoA startup, shutdown, and malfunction plan is not required for these standards.
63.10(d)(1)Yes
63.10(d)(2)Yes
63.10(d)(3)NoSubpart O does not contain opacity or visible emissions standards.
63.10(d)(4)Yes
63.10(d)(5)NoA startup, shutdown, and malfunction plan is not required for these standards.
63.10(e)(1)Yes
63.10(e)(2)(i)Yes
63.10(e)(2)(ii)NoOpacity monitors are not required for these standards.
63.10(e)(3)(i)–(iv)Yes
63.10(e)(3)(v)No§ 63.366(a)(3) specifies contents and submittal dates for excess emissions and monitoring system performance reports.
63.10(e)(3)(vi)–(viii)Yes
63.10(e)(4)NoOpacity monitors are not required for these standards.
63.10(f)Yes
63.11Yes
63.12–63.15Yes